Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client




Features and Benefits
- IEEE 802.11a/b/g/n AP/bridge/client support
Easy setup and deployment with AeroMag
Client-based millisecond-level Turbo Roaming
Complete redundancy with AeroLink Protection
Integrated antenna and power isolation
-40 to 75°C operating temperature range (-T models)
5 GHz DFS channel support
Introduction
The AWK-3131A 3-in-1 industrial wireless AP/bridge/client meets the growing need for faster data transmission speeds by supporting IEEE 802.11n technology with a net data rate of up to 300 Mbps. The AWK-3131A is compliant with industrial standards and approvals covering operating temperature, power input voltage, surge, ESD, and vibration. The two redundant DC power inputs increase the reliability of the power supply, and the AWK-3131A can be powered via PoE to make deployment easier. The AWK-3131A can operate on either the 2.4 or 5 GHz bands and is backwards-compatible with existing 802.11a/b/g deployments to future-proof your wireless investments.
Advanced 802.11n Industrial Wireless Solution
- 802.11a/b/g/n compliant AP/bridge/client for flexible deploymentSoftware optimized for long-distance wireless communication with up to 1 km line of sight and external high-gain antenna (available only on 5 GHz)Supports 60 clients connected concurrentlyDFS channel support allows a wider range of 5 GHz channel selection to avoid interference from existing wireless infrastructure
Advanced Wireless Technology
- AeroMag supports error-free setup of your industrial applications’ fundamental WLAN settingsSeamless roaming with client-based Turbo Roaming for < 150 ms roaming recovery time between APs (Client Mode)Supports AeroLink Protection for creating a redundant wireless link (< 300 ms recovery time) between APs and their clients
Industrial Ruggedness
Integrated antenna and power isolation designed to provide 500 V insulation protection against external electrical interference
Hazardous location wireless communication with Class I Div. II and ATEX Zone 2 certifications
-40 to 75°C wide operating temperature models (-T) provided for smooth wireless communication in harsh environments
• WLAN Interface | |
Standards | IEEE 802.11a/b/g for Wireless LAN IEEE 802.11i for Wireless Security |
Modulation (typical) | • DSSS • MIMO-OFDM • OFDM |
Frequency Band for Europe (20 MHz operating channels) | 2.412 to 2.472 GHz (13 channels) 5.180 to 5.240 GHz (4 channels) 5.260 to 5.320 GHz (4 channels) ![]() 5.500 to 5.700 GHz (11 channels) ![]() |
Wireless Security | • WEP encryption (64-bit and 128-bit) • WPA/WPA2 Enterprise (IEEE 802.1X/RADIUS, TKIP and AES) • WPA /WPA2-Personal |
Transmission Rates | 802.11b: 1 to 11 Mbps 802.11a/g: 6 to 54 Mbps 802.11n: 6,5 to 300 Mbps |
TX Transmit Power 802.11a | 23±1.5 dBm @ 6 to 24 Mbps 21±1.5 dBm @ 36 Mbps 20±1.5 dBm @ 48 Mbps 18±1.5 dBm @ 54 Mbps |
TX Transmit Power 802.11b | 26±1.5 dBm @ 1 Mbps 26±1.5 dBm @ 2 Mbps 26±1.5 dBm @ 5.5 Mbps 25±1.5 dBm @ 11 Mbps |
TX Transmit Power 802.11g | 23±1.5 dBm @ 6 to 24 Mbps 21±1.5 dBm @ 36 Mbps 19±1.5 dBm @ 48 Mbps 18±1.5 dBm @ 54 Mbps |
TX Transmit Power 802.11n (2,4 GHz) | 23±1.5 dBm @ MCS0/8 20 MHz 18±1.5 dBm @ MCS7/15 20 MHz 23±1.5 dBm @ MCS0/8 40 MHz 17±1.5 dBm @ MCS7/15 40 MHz |
TX Transmit Power 802.11n (5 GHz) | 23±1.5 dBm @ MCS0/8 20 MHz 18±1.5 dBm @ MCS7/15 20 MHz 23±1.5 dBm @ MCS0/8 40 MHz 17±1.5 dBm @ MCS7/15 40 MHz |
18 dBm @ 2,4 GHz 21 dBm @ 5GHz (UNII-1 & UNII-2) 23 dBm @ 5GHz (UNII-2e) |
|
RX Sensitivity | 802.11a: -90 dBm @ 6 Mbps, -88 dBm @ 9 Mbps, -88 dBm @ 12 Mbps, -85 dBm @ 18 Mbps, -81 dBm @ 24 Mbps, -78 dBm @ 36 Mbps, -74 dBm @ 48 Mbps, -72 dBm @ 54Mbps802.11b: -93 dBm @ 1 Mbps, -93 dBm @ 2 Mbps, -93 dBm @ 5.5 Mbps, -88 dBm @ 11 Mbps802.11g: -88 dBm @ 6 Mbps, -86 dBm @ 9 Mbps, -85 dBm @ 12 Mbps, -85 dBm @ 18 Mbps, -85 dBm @ 24 Mbps, -82 dBm @ 36 Mbps, -78 dBm @ 48 Mbps, -74 dBm @ 54 Mbps802.11n (2,4 GHz): -70 dBm @ MCS7 20 MHz, -69 dBm @ MCS15 20 MHz, -67 dBm @ MCS7 40 MHz, -67 dBm @ MCS15 40 MHz802.11n (5 GHz): -69 dBm @ MCS7 20 MHz, -71 dBm @ MCS15 20 MHz, -63 dBm @ MCS7 40 MHz, -68 dBm @ MCS15 40 MHz |
WLAN Operation mode | Access point (AP), Client, Client-Router, Master. Slave, Sniffer |
Antenna | External, 2/2 dBi, Omni-directional |
Antenna Connectors | 2 RP-SMA female |
• Ethernet Interface | |
PoE Ports (10/100/1000BaseT(x), RJ45 connector) | 1 |
Standards | IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1X for authentication IEEE 802.3 for 10BaseT IEEE 802.3ab for 1000BaseT(X) IEEE 802.3af for PoE IEEE 802.3u for 100BaseT(X) |
• Protocol Support | |
General Protocols | Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP, PPPoE, DHCP |
• Interface | |
Antennas | External, 2/2 dBi, Omni-directional |
Connector for External Antennas | 2 RP-SMA (female) |
RJ45 Ports | 1, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection |
Buttons | Reset button |
Console Port | RS-232 (RJ45-type) |
LED Indicators | PWR1, PWR2, PoE, FAULT, STATE, SIGNAL, WLAN, LAN |
Alarm Contact | Relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs | 2 electrically isolated inputs • +13 to +30 V for state “1” • +3 to -30 V for state “0” • Max. input current: 8 mA |
• Physical Characteristics | |
Housing | Metal, providing IP30 protection |
Weight | 860 g |
Dimensions | 52.7 x 135 x 105 mm (2.08 x 5.32 x 4.13 in) |
Installation | DIN-Rail mounting, wall mounting (with optional kit) |
• Environmental Limits | |
Operating Temperature | Standard Models: -25 to 60°C (-13 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5% to 95% (non-condensing) |
• Power Requirements | |
Input Current | 0.6 A @ 12 VDC, 0.15 A @ 48 VDC |
Input Voltage | 12 to 48 VDC, redundant dual inputs or 48 VDC Power-over-Ethernet |
Connector | 10-pin removable terminal block |
Power Consumption | 7,2 W (max.) |
Reverse Polarity Protection | Supported |
• Standards and Certifications | |
Safety | EN 60950-1, UL 60950-1 |
Hazardous Location |
ATEX, Class I Division 2, IECEx |
EMC | EN 61000-6-2/-6-4 |
EMI | CISPR 32, FCC Part 15B Class B |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 PFMF |
Radio | ANATEL, EN 300 328, EN 301 489-1/17, EN 301 893, FCC ID SLE-WAPN008, MIC, NCC, RCM, SRRC, WPC, KC |
Vibration |
IEC 60068-2-6 |
• Reliability | |
MTBF (mean time between failures) | 570,854 hrs |
Standards | Telcordia SR332 |
• Warranty | |
Warranty Period | 5 years |
Details | See warranty @ Moxa |