Industrial five-band GSM/GPRS/EDGE/UMTS/HSPA cellular routers



Features and Benefits
- Five-band UMTS/HSPA 800/850/AWS/1900/2100 MHz
Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
Cellular WAN and Ethernet WAN backup mechanism for a complete path redundancy
Primary and secondary power inputs for power source redundancy
Cellular link redundancy with dual-SIM GuaranLink support
DIN-rail housing and wall-mountable housing
Connect to 4 10/100BaseT(X) devices over an integrated VPN
2 digital inputs and 1 relay output
Centralized private IP management software with OnCell Central Manager
Introduction
The OnCell 5104-HSPA high-performance industrial-grade cellular routers allow up to 4 Ethernet-based devices to simultaneously use a single cellular data account for primary or backup network connectivity to remote sites and devices. It provides the functionality of a cellular router, firewall, and switch in one device and is integrated with Moxa’s GuaranLink function to ensure zero data loss and on-demand cellular communication.
The OnCell 5104-HSPA comes with a built-in relay output that can be configured to indicate the priority of events when notifying or warning engineers in the field, and the two digital inputs allow you to connect basic I/O devices, such as sensors, to the cellular network. The OnCell 5104-HSPA uses 12 to 48 VDC power inputs with a screw-on design for greater reliability, and the Ethernet ports come with 1.5 kV magnetic isolation protection to keep your system safe from unexpected electrical discharges.
Standards | GSM/GPRS/EDGE/UMTS/HSPA |
Band Options | • Five band UMTS/HSPA 800/850/AWS/1900/2100 MHz • Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz |
HSPA+ Data Rate | 14.4 Mbps DL, 5.76 Mbps UL |
EDGE Multi-slot Class | Class 12 |
EDGE Terminal Device Class | Class B |
GPRS Multi-slot Class | Class 12 |
GPRS Terminal Device Class | Class B |
GPRS Coding Schemes | CS1 to CS4 |
Tx Power | GSM900: 2 W UMTS/HSPA: 0.25 W EDGE900: 0.5 W EDGE1800: 0.4 W GSM1800: 1 W |
• WAN Interface | |
Number of Ports | 1 |
Ethernet | 10/100 Mbps, RJ45 connector, Auto MDI/MDIX |
Magnetic Isolation Protection | 1.5 KV built-in |
• LAN Interface | |
Number of Ports | 4 |
Ethernet | 10/100 Mbps, RJ45 connector, auto MDI/MDIX |
Magnetic Isolation Protection | 1.5 KV built-in |
• SIM Interface | |
Number of SIMs | 2 (NOTE: This product does not include a SIM card.) |
SIM Control | 3 V |
• I/O Interface (OnCell 5104-HSPA) | |
Alarm Contact | 1 relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs | 2 electrically isolated inputs • +13 to +30 V for state “1” (On) • +3 to -30 V for state “0” (Off) |
• Software | |
Network Protocols | UDP/TCP, SNTP, ICMP, DDNS, DHCP/BOOTP, PPPoE, PPP, DNS Relay, HTTPS, Telnet, RTSP, IPSec |
Router/Firewall | NAT, port forwarding, static routing |
Authentication | Local user-name and password |
Security | IP filtering |
• Management Software | |
OnCell Central Manager | Centralized management solution for accessing private IPs from the Internet |
• Physical Characteristics | |
Housing | Aluminum, providing IP30 protection |
Weight | OnCell 5004-HSPA: 505±5 g OnCell 5104-HSPA: 645±5 g |
Dimensions | OnCell 5004-HSPA: 158 x 103 x 34 mm (6.22 x 4.06 x 1.34 in) OnCell 5104-HSPA: 135 x 50.8 x 103 mm (5.315 x 2.00 x 4.16 in) |
• Environmental Limits | |
Operating Temperature | Standard Models: -30 to 55°C (-22 to 131°F) Wide Temp. Models: -30 to 70°C (-22 to 158°F) |
Storage Temperature | -40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity | 5 to 95% (30°C, non-condensing) |
• Power Requirements | |
Number of Power Inputs | 1 terminal block, 1 power jack |
Input Voltage | 12 to 48 VDC |
Power Consumption | OnCell 5004-HSPA: 12 to 48 VDC, 400 mA (Idle), 900 mA (max.) OnCell 5104-HSPA: 12 to 48 VDC, 450 mA (Idle), 950 mA (max.) |
• Standards and Certifications | |
Safety | UL 60950-1 |
EMC | EN 55022 Class A, EN 55024, FCC Part 15 Subpart B Class A |
Radio | FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 489-24, EN 301 511 |
• Reliability | |
MTBF (mean time between failures) | OnCell 5004-HSPA: 441,000 hrs OnCell 5104-HSPA: 411,000 hrs |
• Warranty | |
Warranty Period | 5 years |
Details | See warranty |